BRIEF DESCRIPTION

With this option, the Pipe Rack Jack is fixed so that it is possible to load the spindles differently and independently.

    Applications:

  • Lining up and welding together 2 pipes.
  • Sawing away a damaged part of a pipe and replacing by a new section.

    Restriction:

  • To avoid damaging the profile, it’s necessary to take care the difference in load of the spindles doesn’t become too big.
  • See folder (click here) for the maximum allowed difference in load in relation to the thickness of the vertical flange of the profile.

MAXIMUM ALLOWED DIFFERENCE IN LOAD OF THE SPINDLES

Thickness vertical flange in inchesMaximum difference in pounds
1/842
5/3265
3/1694
7/32127
1/4166
9/32210
5/16260
11/32314
3/8374
13/32439
7/16509
15/32585
1/2665
17/32751
9/16842
19/32938
5/81039
3/8374